Material |
Stainless steel and steel components on aluminum chassis |
Strikes |
Steel |
Vertical rods |
Aluminum |
Handing |
This device ships RHR and is quick field-reversible |
Device Lengths |
Short - 36”: 33-15/32” (850mm)
Long - 48”: 44-3/4” (1137mm)
|
Door Widths |
36”- For 29” to 36” (736mm to 914mm) door size
48” - For 33” to 48” (838mm to 1219mm) door size
|
Minimum Stile Width |
4-1/4” (107mm) Top latch - 5/8” (16mm) throw, can be deadlocked automatically |
Latch Bolt Strikes |
Top - 403 (panic), 403F (fire).
|
Dogging Kit |
Panic device - Hex key dogging (RD) standard
Fire device - No mechanical dogging (ND)
|
Dogging Options |
Cylinder Dogging (CD)
Less Dogging (LD)
|
Mounting Fasteners |
Panic device - Machine screws furnished standard SNB furnished for top & bottom latches
Fire device - Six nuts and bolts (SNB) supplied standard SNB are required to use for wood doors, order SNB separately
|
Mounting Heigh |
Device centerline from finished floor is 40"(1016mm) standard
|
Door Opening |
Height Standard door height is 7. (8’is available)
|
Vertical Rods |
1/2” (13mm) diameter tubular with rod guides
|
Projection |
Pushbar Neutral:3-1/16” (78mm)
Pushbar Depressed: 2-19/32” (66mm)
|
Finish |
603, 605, 612, 613, 625, 626, 630, 689
|
Certification |
ANSI /BHMA: Tested and certified to the requirements of ANSI/BHMA A156.3 Exit Devices Grade 1
UL Listed : Panic Exit Hardware, or 3-hour Fire Exit Hardware
|
Note:
These LBR devices had been re-tested or approved by two nationally recognized test laboratories. Fire-rated LBR device must use with a UL listed Fire Latch Bolt